Mobile Test Unit HF491
The Mobile Test Unit HF491 enables workshops to test Cummins PT pumps on existing test stands as long as it meets the necessary power and speed requirements. The HF491 will handle the latest higher flow rated Cummins pumps such as those fitted to the 'K' range engines. The Mobile Test Unit HF491 includes all of the essential features of the HA123 Test Stand. A comprehensive range of brackets and couplings are available to enable the HF491 to be used with most Hartridge and other test stands. The Mobile Test Unit HF491 can also be supplied with an optional Aneroid/AFC Test Unit HF109 which is recommended for normal use.

Main Features
Speed of Operation
The Mobile Test Unit HF491 is easily manoeuvred on its nylon castors to wherever it is needed. It also has its own self contained test oil tank, which permits testing of Cummins PT pumps without the need to change the test oil used in the test stand.
Accuracy
The fuel system incorporates a heater and cooler which ensures close control over test oil temperatures and hence accuracy and repeatability of test results.
Versatility
The HF491 is supplied complete with accessories including a pump bracket, ready for immediate use on Hartridge test stands. When used with other mounting manufacturers' test stands a pump mounting plate HM922 is available as an additional accessory, which can be adapted to the standard pump mounting bracket supplied with the test stand.
Driving Motor
Some Cummins PT pumps are tested at speeds of around 3500 rpm, it is therefore essential that the driving test stand be capable of providing sufficient power at these speeds. As a general guide, the test stand driving motor should be a minimum of 5hp with a drive gear efficiency approaching 90% at the required speeds.
Servicing
Maintenance is simple, the filters and test oil can be replaced in minutes.
Benefits
| TECHNICAL SPECIFICATION | |||||||||
|
|
||||||||
|
|
||||||||
| Thermometer | 3 inch diameter, 50-150°F (10-65°C). | ||||||||
| Main Flowmeter | Continuous reading, dual scale glass flowmeter, individually calibrated.75-620lb/hour and 600- 2400lb/hour; total scale length approx. 36 1/2, inches; accuracy +/-1% Plumb-bob level indicator. | ||||||||
| Secondary Flowmeter | For throttle-leakage. Glass scale, calibrated 10 to 760cc/min; scale length approx. 8 1/2 inches. | ||||||||
| Fuel System | 5 Imperial gallons (22.5 litres) capacity; with 1 kw heater. | ||||||||
| Temperature Control | Fuel temperature automatically controlled within +/- 2°F by electric heater and unique contra-flow water cooling system. | ||||||||
|
|
||||||||
| Mobile Trolley | Fitted with four large, swiveling nylon castors and complete with accessories tray to hold pipes, pumps, and tools. | ||||||||
| Electrical Supply | Single Phase 110V 60Hz Single Phase 220V 60Hz Single Phase 220V 50Hz |
||||||||
Additional Accessories
Ordering
The Mobile Test Unit HF491.01 is complete as per specification.
N.B. Available in three different electrical supplies:
Shipping
| Gross Weight: | 137 kgs |
| Net Weight: | 83 kgs |
| Case Size: | 185 x 66 x 68 cms |